2025.02.14
【问题描述】
(1) 1.0-0-str-20250214-01.log
[ERR]sch timeout 0,0x2,789,18,784,4,0,0
[ERR]sch timeout 0,0x13,803,8,800,4,0,0
(2) 2.0-0-str-20250214-02.log
mac log:
wnFapiPhyRecvMsg | Fapi_PhyRecvMsg tti time [282, 16]
wnFapiPhyRecvMsg | Fapi_PhyRecvMsg tti time [289, 5]
phy log:
0-0-str-20250214-02.log中有sfn282 ~ sfn289的slot indicate
log中的STC也可以看出TTI漂移满足要求。
文件
历史记录
由 战 弋戈 更新于 4 个月 之前
[315, 9]
[315, 10]
[315, 11]
[318, 16]
[318, 17]
[318, 18]
[318, 19]
[319, 0]
[319, 1]
[319, 2]
[319, 3]
[319, 4]
[319, 5]
[319, 6]
[319, 7]
[319, 8]
[319, 9]
[319, 10]
[319, 11]
[319, 12]
[319, 13]
[318, 2]
[318, 3]
[318, 4]
[318, 5]
[318, 6]
[318, 7]
[318, 8]
[318, 9]
[318, 10]
根据对tti time 过滤出来的tti的打印, 存在中间tti丢失乱序的问题,比如[315, 11]
突然到了 [318, 16] ,到了[319, 13] 又突然到了[318, 2]